Warehouse Partition Control, Rust Maintenance and In-out Management Standard of Precision Stainless Steel Fasteners

Warehouse Partition Control, Rust Maintenance and In-out Management Standard of Precision Stainless Steel Fast

Different from ordinary carbon steel fasteners, austenitic stainless steel fasteners are easy to produce surface fog, spot rust and thread adhesion due to moisture, metal contact and dust pollution in ordinary warehouse. Unclassified mixed storage will cause mass inventory scrap, order delivery error and increased enterprise procurement cost. Based on national hardware warehouse protection standards, this paper puts forward complete partition management, regular maintenance and standardized inbound and outbound rules for high-precision stainless steel screws, nuts and combination fasteners, which can be directly applied to distributors and processing

1. Eight Functional Zones Division and Storage Rules

The precision fastener warehouse shall be divided into eight closed independent zones with constant temperature 18-26℃ and humidity 40%-60%. The incoming inspection zone is used for moisture dissipation of new goods. Independent storage zones separate 304, 316L and carbon steel fasteners completely to avoid galvanic corrosion. Isolation area for defective products can prevent defective goods from being delivered by mistake. All goods shall be placed away from wall and ground to prevent moisture regain.

2. Warehouse Defect Cause and Rectification Comparison Table
Defect Phenomen Emergency SolutionLong
Surface YellowingHumidity Over 6Clean With Special Anti-rust OilEquip Dehumidifier, Double Moisture-proof Package
Iron Scrap Adhesion, Mixed StoragePassivation ReprocessingCompletely Isolate Carbon Steel GoodsThread SeizureStacking Extrusion, No Disassemble With Anti-seize GreasePack Small Screws In Plastic BoxPlacing Replace Package And DryKeep Distance From Wall And Ground
Mixed Specification StockMissing Label, Random StackingScreen And Relabel All GoodsOne 3. Regular Hierarchical Anti-rCarry out inspection every 15 days for conventional 304 fasteners, inspect every 10 days for corrosion-resistant 316L fasteners and add anti-rust oil properly. Micro electronic screws shall be stored in sealed boxes with desiccant replaced monthly. Keep dehumidifier running all day in rainy season to control indoor humidity steadily

4. Standard InboundInbound: Check material certificate → inspect appearance → classify and shelf → paste traceability label → record inventory data. Outbound: Confirm order information → inspect appearance quality → adopt first-in first-out rule → pack tightly → register delivery data. It is forbidden to deliver mixed, rusty and unqualified fasteners

5. Warehouse Operation Pro

Do not remove original moisture-proof package without permission, avoid scratching fastener surface during handling, never store different metal fasteners together, forbid storing chemical corrosive materials inside the warehouse, and complete inventory checking during staff handover.